- General
- Shell Metal material
- Net Weight 2.13 kg (4.70 lb)
- Gross Weight 3.1 kg (6.8 lb),3.0 kg (6.6 lb)
- Dimensions (W × H × D)335.00 mm × 44.50 mm × 226.00 mm (13.19” × 1.75” × 8.90”)
- Operating Temperature 0 °C to 45 °C (0 °F to 113 °F)
- Storage Temperature -40 °C to 85 °C (-40 °F to 185 °F)
- Operating Humidity 5% to 95% (no condensation)
- Relative Humidity 5% to 95% (no condensation)
- Power Supply 100-240 VAC, 50/60 Hz, Max. 6.5 A
- Installation Mode Rack (equipped with mounting ears)
- Max. Power Consumption 250 W
- Power Consumption In Idle 10 W
- Surge Protection 6 KV
- Network Parameters
- Ports 24 × 10/100 Mbps PoE port,2 × Gigabit combo
- MAC Address Table 16 K
- Switching Capacity 14.8 Gbps
- Packet Forwarding Rate 11.01 Mpps
- Internal Cache4 Mbits
- PoE Power Supply
- PoE Standard IEEE 802.3af,IEEE 802.3at
- PoE Power Pin 8-pin power: 1/2(-), 3/6(+), 4/5(+), 7/8(-)
- PoE Port PoE: Ports 1 to 24
- Max. Port Power 30 W
- PoE Power Budget 230 W
- Software Function
- Long Range
Ports 1 to 24: up to 300 m.
Long range performance may vary depend on camera model or cable condition.
- VIP Port Ports 1 to 8: data on VIP ports is preferentially forwarded when bandwidth resources are insufficient.
- Link Aggregation
Link aggregation is used to aggregate multiple physical ports to form a logical port for load balancing, bandwidth expansion, and port protection.
Support static link aggregation.
Support 1 aggregation groups.
- HPP
Support one-click activation and remote management via Hik-Partner Pro. Functions supported:
1. Display the port rate.
2. Display the port bandwidth utilization rate.
3. Display the PoE power usage.
4. Display topology information.
5. Display the alarm status.
6. Restart ports and devices.
7. Enable port long-rage mode.
8. Remotely upgrade the device.
- PoE Watchdog Ports 1 to 24: auto detect and restart the cameras that do not respond.
- System Maintenance Support remote upgrade, default parameter restoration, logs viewing, and basic network parameter configuration.
- Approval
- EMCCE-EMC (EN 55032: 2015+A11: 2020, EN IEC 61000-3-2: 2019, EN 61000-3-3: 2013+A1: 2019, EN 50130-4: 2011+A1: 2014, EN 55035: 2017+A11: 2020)
- Safety UL (UL 60950-1),CB (AMD1:2009, AMD2:2013, IEC 62368-1: 2014 (Second Edition), CE-LVD (EN 62368-1: 2014+A11: 2017)
- Chemistry CE-RoHS (2011/65/EU),WEEE (2012/19/EU),Reach (Regulation (EC) No.1907/2006)
Reviews
There are no reviews yet.